Example
200 L; 0 → 8 bar(g); Q = 250 L/min; Qd = 0; P₀ = 1 bar(a) → 6.4 min.
GOOD TO KNOW
How is this result calculated?
t (min) = V (L) × (P₂ − P₁) (bar) / [Pambient (bar absolute) × (QFAD − Qdemand) (L/min)]. Isothermal estimate at equal tank and inlet temperatures. Use FAD at the actual working pressure, not piston displacement. Constant delivery assumed; cooling, leaks and pressure-dependent delivery change the result.