Report a problem

ENGINEERING TOOL

Compressor Power Calculator

Estimate ideal isentropic power, shaft power and electrical input for single-stage air compression.

Compressor Power Calculator

FREE ONLINE TOOL

Ideal isentropic power

4.761 kW

Shaft power

6.348 kW

Electrical input

7.0534 kW

Pressure ratio

7.9085

Understanding your result

Electrical input exceeds shaft power because of motor losses. This is a simplified isentropic estimate; compare it with manufacturer data at the same inlet conditions and discharge pressure.

Saved scenarios

Saved locally in this browser; no data is uploaded.

Formula and assumptions

Pis = k/(k−1) × P1 × Q1 × [(P2/P1)^((k−1)/k) − 1]; Pshaft = Pis/ηis; Pelec = Pshaft/ηmotor; k = 1.4

Use absolute pressures and actual volumetric flow at the inlet. Single-stage ideal-gas air model with k = 1.4; excludes intercooling, auxiliaries and package losses. Isentropic power is not the isothermal minimum. Compare with manufacturer package input data.

Technical reference: Atlas Copco — Compressed Air Manual

Continue your task

Use consistent airflow and pressure conditions between steps.

Which tool fits your task?

Compare the purpose of these tools before choosing.

IN PRACTICE

Example

P1 = 1.01325 bar(a); P2 = 8.01325 bar(a); Q1 = 1 m³/min; ηis = 75%; ηmotor = 90%.

GOOD TO KNOW

Which model does this calculator use?

Use absolute pressures and actual volumetric flow at the inlet. Single-stage ideal-gas air model with k = 1.4; excludes intercooling, auxiliaries and package losses. Isentropic power is not the isothermal minimum. Compare with manufacturer package input data.